Clay-paky ALPHA SPOT HPE 700 Manuel d'utilisateur Page 21

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 20
21
ALPHA SPOT HPE 700
LAMP HOURS
Used for displaying the lamp working hours (total and partial).
1) Press
F
- Hours total and partial appears on the display.
Total counter
Counts the number of projector working hours with the lamp on (from
manufacture to date).
Partial counter
Counts the number of lamp working hours since the last reset to date.
2) Press
F
to reset partial lamp working hours, a confirmation message
(
Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting
and return to the top menu level
LAMP STRIKES
U
sed for displaying the number of times the lamp was turned on (total and
partial).
1) Press
F
- the number of times the lamp was turned on (total and
partial) appears on the display.
Total counter
C
ounts the number of times the lamp was turned on (from manufacture
to date).
Partial counter
Counts the number of times the lamp was turned on since the last reset
to date.
2) Press
F
to reset partial lamp strikes hours, a confirmation message
(Are you sure ?) appears on the display.
3) Select YES to reset partial counter or NO to keep the current setting
and return to the top menu level
SYSTEM VERSION
Used for displaying the software and hardware version of each board
installed in the projector.
CPU brd (CPU board)
0: PT-3f (Pan / Tilt board)
1: 8-Ch (8 channel board)
2: 8-Ch (8 channel board)
BOARD DIAGNOSTIC
Used for displaying the status error of each board installed in the projector:
0: PT-3f (Pan / Tilt board)
1: 8-Ch (8 channel board)
2: 8-Ch (8 channel board)
DMX MONITOR
Used for displaying the projector DMX channel level in bit (Val) and in
percentage (Perc).
FANS MONITOR
Used for displaying the speed of each fan installed in the projector:
Ball. IN (Ballast IN Fan)
Eff.IN (Effects IN Fan)
Lamp (Lamp Fan)
SENSOR STATUS
It lets you check the correct operations of each "sensor” installed in the
projector, each channel is associated with one of the following three
parameters:
• n.a.= sensor not available
• ON= sensor working
• OFF= sensor defective
NETWORK PARAMS
Allows the "Network" parameters of the projector to be displayed or:
IP address: Internet Protocol address (two projectors must not have the
same IP address)
IP mask: 255.0.0.0
Mac address: Media Access Control: the projector’s Ethernet Address
Lamp
Strikes
Total XXX
Partial XXX
Reset...
Lamp
Hours
Total XXX
Partial XXX
Reset...
Continue
Network
params
System
Version
Board Revis. Hw.rv.
CPU brd x.x.x x.x
com.dev x.x
0: PT-3f x.x x.x
1: 8-Ch x.x x.x
2: 8-Ch x.x x.x
Board
Diagnost.
Dmx
Monitor
Board Status Err%
0:PT-3f Good 0.00
1:8-Ch Good 0.00
2:8-Ch Good 0.00
Fans
Monitor
Fan Speed (RPM)
Ball.In. XXXX
Eff.In XXXX
Lamp XXXX
Sensor
Status