ALPHA SPOT HPE 700
CALIBRATION
Allows you to adjust effects from the control panel to obtain perfect unifor-
mity between the projectors.
1) Press
F
- “channels” appears on the display.
2) Using the UP
B
and DOWN
C
keys, select the effect you wish to
regulate.
3) Press
F
and use the RIGHT
E
, UP
B
and DOWN
C
buttons to
make the adjustment by setting a value between 0 and 255.
4) Press
F
to confirm the selection
or
LEFT
D
to keep current settings
and return to the top level.
FACTORY DEFAULT
Allows you to restore default values of all channels (128).
1) Press
F
– a confirmation message appears on the display (Reset
calibration to factory default ?).
2) Select YES to reset calibration to factory default or NO to keep the
current setting and return to the top menu level.