Clay-paky STORMY CC Manuel d'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
15
PRELIMINARY
5.1 SET-UP MENU
SET UP - DMX ADDRESS
It allows to set DMX address to be assigned to the projector, it’s possible to select a DMX address between
1 and 512.
> NOTE: In case of absence of DMX input signal, the displayed projector address ashes.
SET UP - CHANNEL MODE
It allows to set the operation mode of the projector selecting from the following:
Standard: max 7 DMX channels occupied for “Stormy CC” / max 3 DMX channels occupied for “Stormy”.
Xenon: max 4 DMX channels occupied for “Stormy”
Independent: max 14 DMX channels for “Stormy CC”
SET UP - FIXTURE ID
It allows to set a “Fixture ID” to be assigned to the projector, for easier identifcation of the same projector in
an installation. It’s possible to select a “Fixture ID” between 1 and 255.
5.2 OPTIONS MENU
OPTION - DIMMER CURVE
It allows the selection of one of the following two Dimmer curves:
Curve 1
Curve 2
OPTION - MINIMUM TON VALUE
It allows the set the minimum “T ON” duration of strobe ash under which it’s not possible to come down. It’s
possible to select a value between 0 and 255.
With the “Duration” channel you set the fash duration. At every level of the DMX signal corresponds
a duration. The value Minimum T ON valuerepresents the level of the DMX channel Duration under which
the TON value does not change.
OPTION - LED MODE
It allows the selection of one of the following two methods of LEDs management
Row: RGBW channels are independent.
Balance: RGBW components are optimized to have a white color with maximum light output.
OPTION - SILENT MODE
It allows the selection of one of the following two alternatives:
Standard: Maximum fans’ speed; therefore maximum noise level and maximum light output of the LEDs.
Quiet:
It reduces the fans’ speed and, as a consequence, the noise; the maximum brightness of the LEDs
.
It
reduces
also subject to decrease according to the conditions of use (ambient temperature, used effect
type).
STORMY C71090
STORMY CC C71091
Vue de la page 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 29 30

Commentaires sur ces manuels

Pas de commentaire